Stahl - 150638 ürününün fiyatını ve teslimat süresini öğrenmek için lütfen sorunuzu bize e-postayla gönderin. Diğer model numaraları için de size tavsiyelerde bulunabiliriz. Alman endüstriyel pazarında sizin için en iyi fiyatı ve teslimat süresini bulmaya çalışıyoruz.
Yalnızca yeni ve orijinal ürünler satıyoruz.
8491/11-230 Hupe mit Horn 230V, AC
8491/21-230 Flachhupe 230V, AC
8570/12-306 Plug 2P+PE 16A 200-250V, 60+60Hz, 6h, blue
(Push button explosion-protected Type : 8602A0001-1 Enclosure material : Polyamide Seal : Standard Mounting : with threaded Application range (Zone) : 1 , 2 , 21 , 22 Gas explosion protection : II 2 G Ex e II Dust explosion protection : II 2 D Ex tD A21 Min. ambient temperature : -20 °C Max. ambient temperature : +70 °C Type of protection (IP) : IP66 Packed : Yes)
(Rotary handle, large, raised explosion-protected Type : 8602A0724-1-ss-0 Enclosure material : Polyamide Seal : Silicone Mounting : with threaded Padlockable in : no position Application range (Zone) : 1 , 2 , 21 , 22 Gas explosion protection : II 2 G Ex e II Dust explosion protection : II 2 D Ex tD A21 Min. ambient temperature : -50 °C Max. ambient temperature : +70 °C Type of protection (IP) : IP66 Packed : Yes)
(Label I O II)
labels buttons series 8003
Anahtar amplifikatörü dijital giriş
IS PAC Isolating Repeater Switching Repeater Field Circuit Ex i explosion-protected Type : 9170/10-12-21s Max. Voltage Uo : 10,6 V Max. Current Io : 24 mA Max. Demand Po : 64 mW Min. nominal voltage : 120 V Max. nominal voltage : 230 V Nominal current : 12 mA Number of channels : 1 Output / channel : 1 change over contact LFD relay : Yes Line fault transparency : No Min. ambient temperature : -20 °C Max. ambient temperature : +70 °C Dust explosion protection : II (1) D [Ex ia] IIIC For further information, see : www.r-stahl.com Web code 9170A Switching Repeater Series 9170, Field Circuit Ex i, single channel Basic function: binary / digital input Intrinsically safe input: [Ex ia] IIC Power supply: 120 ... 230 V AC Input: acc. to EN 60947-5-6 (NAMUR) Output / channel: 1 change-over contact Connection type: Screw terminals
(Notlicht-Langfeldleuchte für Leuchtstofflampen Typ: 6608/5.2-9...-...7 Technische Daten: Gas-Explosionsschutz: II 3 G EEx nAC II T4 Staub-Explosionsschutz: II 2 D T 80°C Prüfschein: DMT 03 E 093/ ATEX E 094 X Geeignet für: Leuchtstofflampe 2Stift, 2 x 18W Reflektorausführung: symmetrisch breitstrahlend Material: Polyesterharz Oberfläche: Ohne Farbgebung Schutzart: IP 66 Umgebungstemperatur: -20°C...40°C Nennspannung: 220 V -10% ... 254 V +10%; 50/60 Hz Kabeleinführung: 2 x Kabeleinführung M25x1,5 1 x Verschlussstopfen M25x1,5 ohne Leuchtmittel Durchverdrahtung mit 6 Leitern Abschaltung beim öffnen der Leuchte (Netzspannung und Batteriekreis) mit Betriebsdauertest)
Reparatursatz 2x36W QTP8 Ers.QTIS-B Elektronisches Vorschaltgerät + Zubehör
Reparatursatz 2x18W QTP8 Ers. QTISElektronisches Vorschaltgerät + Zubehör
Control Pendant selection STH 6102-009
Switch socket 3P+N+PE 63A, 200/346-240/415V, 50+60Hz, red CCT No.: 85366990 DE Net weigth: 7,800 KG
Switch socket 3P+N+PE 63A, 200/346-240/415V, 50+60Hz, red CCT No.: 85366990 DE Net weigth: 7,800 KG
Anahtar priz patlamaya karşı korumalı
(Safety Switches 16 A explosion-protected Rated operational voltage AC : 400 V Rated operational current : 16 A Enclosure material : Polyester resin glass fibre-reinforced Detailed number of poles : 3 P Auxiliary contact NC : without Auxiliary contact NO : 1 NO lagging Application range (Zone) : 1 , 2 , 21 , 22 Gas explosion protection : II 2 G Ex de IIC T6 Gb Dust explosion protection : II 2 D Ex tb IIIC 80 °C Db Min. ambient temperature : -40 °C Max. ambient temperature : +51 °C Special conditions for extended ambient temperature, see operating instructions: Extended min. ambient temp. : -40 °C Extended max. ambient temp. : +69 °C Type of protection (IP) : IP66 Colour of handle : standard black Cable gland : 2 x M25 Ø 7 ... 17 mm 1 x M20 Ø 6 ... 13 mm Connection cross-section : 2,5 ... 6 mm2 Connection cross-section aux.: 1,5 ... 4 mm2 finely-stranded 1,5 ... 6 mm2 solid CCT No.: 85365080 DE Net weigth: 1,590 KG)
(Safety Switches 16 A explosion-protected Rated operational voltage AC : 400 V Rated operational current : 16 A Enclosure material : Polyester resin glass fibre-reinforced Detailed number of poles : 3 P Auxiliary contact NC : without Auxiliary contact NO : 1 NO lagging Application range (Zone) : 1 , 2 , 21 , 22 Gas explosion protection : II 2 G Ex de IIC T6 Gb Dust explosion protection : II 2 D Ex tb IIIC 80 °C Db Min. ambient temperature : -40 °C Max. ambient temperature : +51 °C Special conditions for extended ambient temperature, see operating instructions: Extended min. ambient temp. : -40 °C Extended max. ambient temp. : +69 °C Type of protection (IP) : IP66 Colour of handle : standard black Cable gland : 2 x M25 Ø 7 ... 17 mm 1 x M20 Ø 6 ... 13 mm Connection cross-section : 2,5 ... 6 mm2 Connection cross-section aux.: 1,5 ... 4 mm2 finely-stranded 1,5 ... 6 mm2 solid CCT No.: 85365080 DE Net weigth: 1,590 KG)
6141/61-16 Hand lamp with LED Hand Lamp Series 6141/6, explosion protected Rated data: 3 V Batteries: Hand lamps are supplied with batteries. For other battery types see operating instructions For use in: Zones 1 & 2, 21 & 22
Fiber optik üst parça
Kemer çantası
YO3/ISC/T4 ATX YO3 Hupe Ex i ATEX, T4
YO5/ISC/T6 ATX YO5 Hupe Ex i ATEX, T6
MCP/PB/SP/Ex/A+B+C+D/EU/R/LED/D/T Drucktaster-Handfeuermelder, 12-50VDC/
Batterie 6148 6V 4,5Ah replacement set
Batterie 6148 6V 4,5Ah replacement set
Diffusing lens clear accessories
Diffusing lens clear accessories
Befehls- und Meldegeraet